CLEAN BURNER ASSEMBLY |
to improve combustion, reducing waste heat |
TUNE BURNERS |
for more efficient burns, saving energy |
CLEAN IGNITION ASSEMBLY |
to ensure reliable operation on demand |
CLEAN & INSPECT FURNACE HEAT SECTION |
to ensure safe operation and the absence of cracks from metal fatigue |
VERIFY FLUE DRAFT |
to ensure dangerous gas by-products are properly venting to the outdoors and flue pipes are free from obstruction |
INSPECT FLUE PIPE |
to ensure no corrosion is present which can lead to cracks and the introduction of dangerous fumes into your home |
TEST REFRIGERANT CHARGE |
to ensure optimum levels leading to lower utility usage and extend compressor life |
TEST CAPACITORS |
to ensure reliable operation and continued compressor and motor protection |
TEST CRANKCASE HEATERS |
to ensure proper compressor protection |
INSPECT & TEST CONTROLS & SAFETIES |
to keep operating costs low and prevent failures |
CLEAN OR REPLACE FILTERS |
to reduce energy use, reduce compressor strain, improve indoor air quality, and improve comfort |
CLEAN & ADJUST BLOWER ASSEMBLY |
to extend motor life, improve air quality, and reduce sound |
CHECK AIR FLOW |
to ensure proper air flow across the coil for proper humidity removal and reliable operation |
VISUALLY INSPECT DUCTWORK |
to identify obvious leaks, which reduce system efficiency and increase utility expense |
TIGHTEN ELECTRICAL CONNECTIONS |
to ensure uninterrupted system operation |
MEASURE & RECORD VOLTAGE & AMPERAGE |
to identify baseline operating conditions |
LUBRICATE ALL MOVING PARTS |
to maintain efficiency and extend equipment life |
CLEAN INSIDE EVAPORATOR COIL |
to restore heat transfer efficiency, reduce utility cost, and improve air quality |
CLEAN OUTSIDE CONDENSING COIL |
to restore heat transfer efficiency and reduce utility cost |
CLEAN CONDENSATE DRAINS |
to prevent water damage and the potential for mold formation |